- Name
- Description
- Cat#
- Pricings
- Quantity
Catalogue number
ENZ-832
Synonyms
UDP-Glucose Pyrophosphorylase 2,UDP-Glucose Pyrophosphorylase 1, EC 2.7.7.9, UGPP2, UDPGP, UGP1, UTP--Glucose-1-Phosphate Uridylyltransferase 2Uridyl Diphosphate Glucose Pyrophosphorylase-1, Uridyl Diphosphate Glucose Pyrophosphorylase 2, UTP--Glucose-1-Phosphate Uridylyltransferase , UTP-Glucose-1-Phosphate, Uridyltransferase, UDP-Glucose Pyrophosphorylase , UDP-Glucose Diphosphorylase, UGPase 2, UDPGP2, PHC379, UGPase, UGPP1, UDPG.
Introduction
UDP-Glucose Pyrophosphorylase 2, also known as UGP2 is an essential intermediary in mammalian carbohydrate inter
conversions. UGP2 transfers a glucose moiety from glucose-1-phosphate to MgUTP and forms UDP-glucose
and MgPPi. UDP-glucose is a direct precursor of glycogen in the liver and
muscle tissue, moreover in lactating mammary gland it is converted to
UDP-galactose which is next converted to lactose.
Description
UGP2 Human Recombinant produced in E.Coli is a single, non-glycosylated polypeptide chain containing 531 amino acids (1-508 a.a) and having a molecular mass of 59.3kDa.
UGP2 is fused to a 23 amino acid His-tag at N-terminus & purified by proprietary chromatographic techniques.
UGP2 is fused to a 23 amino acid His-tag at N-terminus & purified by proprietary chromatographic techniques.
Source
Escherichia Coli.
Physical Appearance
Sterile filtered colorless solution.
Formulation
UGP2 protein solution (0.25mg/ml) containing Phosphate buffered saline (pH7.4) 30% glycerol and 1mM DTT.
Stability
Store at 4°C if entire vial will be used within 2-4 weeks.
Store, frozen at -20°C for longer periods of time.
For long term storage it is recommended to add a carrier protein (0.1% HSA or BSA).
Avoid multiple freeze-thaw cycles.
Store, frozen at -20°C for longer periods of time.
For long term storage it is recommended to add a carrier protein (0.1% HSA or BSA).
Avoid multiple freeze-thaw cycles.
Purity
Greater than 90.0% as determined by SDS-PAGE.
Amino acid sequence
MGSSHHHHHH SSGLVPRGSH MGSMSRFVQD LSKAMSQDGA SQFQEVIRQE LELSVKKELE KILTTASSHE FEHTKKDLDG FRKLFHRFLQ EKGPSVDWGK IQRPPEDSIQ PYEKIKARGL PDNISSVLNK LVVVKLNGGL GTSMGCKGPK SLIGVRNENT FLDLTVQQIE HLNKTYNTDV PLVLMNSFNT DEDTKKILQK YNHCRVKIYT FNQSRYPRIN KESLLPVAKD VSYSGENTEA WYPPGHGDIY ASFYNSGLLD TFIGEGKEYI FVSNIDNLGA TVDLYILNHL MNPPNGKRCE FVMEVTNKTR ADVKGGTLTQ YEGKLRLVEI AQVPKAHVDE FKSVSKFKIF NTNNLWISLA AVKRLQEQNA IDMEIIVNAK TLDGGLNVIQ LETAVGAAIK SFENSLGINV PRSRFLPVKT TSDLLLVMSN LYSLNAGSLT MSEKREFPTV PLVKLGSSFT KVQDYLRRFE SIPDMLELDH LTVSGDVTFG KNVSLKGTVI IIANHGDRID IPPGAVLENK IVSGNLRILD H.
Safety Data Sheet
Usage
ProSpecs products are furnished for LABORATORY RESEARCH USE ONLY. They may not be used as drugs, agricultural or pesticidal products, food additives or household chemicals.